Use:
The valve is intended for installation in distribution networks of natural gas, lighting gas or bottle gas from 15 mbar up to 100 mbar for supply of household gas appliances at which the inlet gas pressure is reduced before the valve.
This valve is equipped with:
- Child lock: Safety system on the cock, which prevents its opening if the cock is not pushed during the act;
- Flow protection: Integrated safety closure system which automatically interrupts gas flow if the hose behind the cock bursts or is cut through or if the maximum flow value indicated on the cock is exceeded, in which way dangerous gas leak is prevented;
- Thermal protection: Thermal safety system which automatically closes the gas flow if the valve is exposed to temperature above 100 °C, in which way it prevents further gas leak and remains for at least 30 minutes at the temperature of 650 °C to prevent the risk of explosion.